You can configure a Streamvault™ manager entity to control the alert configurations of
a group of Streamvault™ hardware monitors from a single location. You can also set up
notifications to be raised when problems occur. Using the Streamvault manager entity is
optional.
Note: The Streamvault manager entity can run on any Streamvault or
non-Streamvault server in your Security Center system. Only one Streamvault manager entity
can be added to the system.
Procedure
In Config Tool, navigate to the Plugins task and select the
Streamvault plugin role.
Right-click the Streamvault plugin role and click Create
manager.
Select the Streamvault manager entity and click the General
tab.
The following sections are displayed:
The iDRAC alert configuration profile section manages
iDRAC-enabled servers in your system.
The Non-iDRAC alert configuration profile section is used to
manage other non-iDRAC servers in the system.
Both sections are always shown, regardless of whether you have an iDRAC or
non-iDRAC system.
(If applicable) In the iDRAC alert configuration profile section,
configure the following:
To manage iDRAC alert configurations through the Streamvault hardware monitor of
the selected server, select the Hardware monitor manages iDRAC alert
configurations checkbox.
Select the checkboxes that correlate with the Events,
Severity levels, and Notification
types that you want to apply to the Streamvault Maintenance plugin instances
controlled by the Streamvault manager.
(If applicable) In the Non-iDRAC alert configuration profile
section, configure the following:
Select the checkboxes that correlate with the Events and
Notification types that you want to apply to the Streamvault Maintenance plugin instances controlled by the Streamvault
manager.
Under Configuration, set the wear Threshold
% of the solid-state drive (SSD) at which you want to receive a
notification to inform you to replace the SSD soon.
In the Email recipients section, choose which users and user
groups receive email notifications when a condition in the iDRAC alert
configuration profile or Non-iDRAC alert configuration
profile section is met.